HESCO area - 5.9 peak-sun hrs/day

Solar calculator for Hyderabad

Hyderabad has strong solar potential and high cooling demand. Use this HESCO page to compare system size, monthly generation, payback, and quote quality before selecting an installer.

Open free online calculatorView estimates
City estimate

Hyderabad solar estimate at a glance

This shared model uses 5.9 peak-sun hours per day, a 75% performance ratio, 55% direct self-consumption, Rs. 60/unit retail value, and Rs. 8.13/unit export credit. These are illustrative assumptions, not an official flat HESCO tariff. Enter the actual units from your bill, then ask your installer to recalculate savings using your agreement rates and measured daytime load.

DISCO
HESCO
Hyderabad Electric Supply Company
Peak sun
5.9
hours per day used for sizing
Province
Sindh
geographic context
Default type
Hybrid
on-grid costs are shown below too
Illustrative load profiles: these scenarios use the shared calculation model. They are not monitored local installations, measured bills or installer quotations. Shops and industrial sites need their actual tariff and operating schedule checked separately.
Use caseMonthly unitsHybrid sizeCost estimateMonthly generationSavingsPayback
Small home350 kWh3 kWRs. 460K - Rs. 540K398 kWhRs. 14,6002.8 years
Family home600 kWh5 kWRs. 760K - Rs. 910K664 kWhRs. 24,3002.8 years
Large home900 kWh7 kWRs. 1.06M - Rs. 1.27M929 kWhRs. 34,1002.8 years
Shop or office1,500 kWh12 kWRs. 1.82M - Rs. 2.18M1,593 kWhRs. 58,4002.8 years
System prices

Hyderabad 5 kW, 7 kW, 10 kW, and 15 kW solar cost guide

These are starting budgets from the shared Pakistan model rather than a local supplier quotation survey. Request separate prices for roof repairs, elevated structures, coastal protection, the exact battery capacity and utility works.

5 kW

On-grid range
Rs. 410K - Rs. 500K
Hybrid range
Rs. 760K - Rs. 910K
Estimated monthly generation
664 kWh

7 kW

On-grid range
Rs. 580K - Rs. 690K
Hybrid range
Rs. 1.06M - Rs. 1.27M
Estimated monthly generation
929 kWh

10 kW

On-grid range
Rs. 830K - Rs. 990K
Hybrid range
Rs. 1.52M - Rs. 1.82M
Estimated monthly generation
1,328 kWh

15 kW

On-grid range
Rs. 1.24M - Rs. 1.49M
Hybrid range
Rs. 2.28M - Rs. 2.72M
Estimated monthly generation
1,991 kWh
Local sizing notes

What changes in Hyderabad

Hyderabad uses a 5.9 peak-sun-hour planning default. For an exposed Latifabad or Qasimabad roof, ask the survey to treat heat, anchoring and water drainage as separate design checks. A strong annual solar assumption cannot show whether a roof is safe to mount or whether summer equipment temperatures are acceptable.

High sun can deliver strong output, but heat, dust, and monsoon weather mean mounting, drainage, and cable routing should be checked carefully.

LatifabadQasimabadHirabadAutobahn RoadCitizen ColonyDefence

Area names are examples for survey planning. Verify the actual electricity supplier on your own bill.

Net billing

HESCO savings logic

HESCO users should maximize direct daytime usage where possible because exported units and imported units have different cash values under net billing.

The calculator separates direct savings from export credit because imported units and exported units have different cash values. This is why two Hyderabad homes with the same kW size can have different payback.

Site survey

Evidence to request for a Hyderabad roof

Use your own bill, roof photographs and operating schedule to turn these local checks into a written design. Ask for the evidence behind each proposal before comparing total prices.

Retain roof drainage and verify exposed mounting

Ask for anchor locations, structural wind checks and the waterproofing method at every roof penetration. The layout should preserve drains and maintenance passages. Photograph existing leakage before work and agree who repairs it if the installation changes water flow.

Avoid treating a hot loft as a ready battery room

Before choosing hybrid equipment, check the intended room's ventilation and the exact battery manufacturer's temperature and clearance requirements. Request the maximum continuous backup load and a compatible inverter/battery list. Include any enclosure or room work in the quote.

A comparison to make before you buy

For a Qasimabad shop that closes in the afternoon, compare its operating hours with solar production before increasing panel size. For a home using afternoon cooling, repeat the comparison with that load profile. These two premises can need different self-consumption assumptions despite sharing the same Hyderabad sun-hours default.

Quote checklist

Before you sign a Hyderabad solar quote

Keep every installer on the same scope. Otherwise a cheaper quote may simply be missing protection gear, stronger mounting, monitoring, battery wiring, or HESCO paperwork.

1

Confirm the HESCO filing scope, fees, drawings, testing, inspection, and bidirectional meter timeline.

2

Ask for panel brand, exact model, wattage, serial verification, product warranty, and performance warranty.

3

Require inverter make, model, warranty channel, monitoring access, surge protection, earthing, and breaker details.

4

Separate panels, inverter, mounting, protection gear, battery, labor, and net-billing filing into line items.

5

Ask Hyderabad installers for mounting details, heat management, battery room ventilation, HESCO filing support, and after-sales availability.

FAQ

Hyderabad solar calculator questions

Answers to local planning questions before you request a quote.

What should be checked on an exposed Hyderabad roof?

Request a written anchoring and wind-load design, waterproofing details, drainage and maintenance paths. Sun-hours do not establish structural safety.

Will a Hyderabad shop and home have the same savings?

Their opening and cooling hours can differ. Use separate load profiles to estimate direct use, exports and evening imports.

Official sources

Verify the application and generation assumptions

Use the original utility sources for application rules, fees and approval steps. The sun-hours and price bands on this page are this site's planning assumptions; they are not an official tariff or a measured local yield dataset.

HESCO official net-billing portal

PITC lists HESCO among its supported utilities and links applications, tracking, NEPRA regulations, contact information and transformer checks. Read the current notices before a new application or capacity change.

Check monthly yield in Global Solar Atlas

Select your roof's location and compare monthly PVOUT for the proposed orientation and tilt. The Atlas model excludes building and vegetation shade, so a local shade survey is still needed. Its kWh/kWp yield is a different quantity from this calculator's peak-sun-hour input.

Read the Atlas methodology

Official links reviewed: 6 October 2026. See the calculator methodology and limits

More cities

Compare nearby solar calculator pages

Compare roof, load and application checks across locations. The shared price model does not establish differences in actual local market prices.

Calculate your Hyderabad solar system from your bill

Start with bill amount, city, and DISCO. No login required.

Open online calculator
WhatsApp